无锡雷宏美电子科技有限公司 Wuxi LHMST electronic technology co., LTD PCO201 ELECTROCHEMICAL SENSOR
----------INSTRUCTION MANUAL---------
PCO201 electrochemical sensor is a high performance, low cost of cell electrochemical sensor type,
can be widely used in civil and family one-piece carbon monoxide gas detection. PCO201 sensor EN50291 UL2034 America and the European Union standards for all kinds of carbon monoxide sensor in the performance of the norms. One、 Product features Real figure:
 Low power consumption                                     Sensitivity                                   Wide range                                    High precision                                     Strong anti interference ability                               Reliable repeatability and stability                      Two、Technical parameters
CATEGORY principle Measuring gas
Range MAX Range Sensitivity Resolution Temperature Pressure Humidity Response time(T90)
Three、The basic test circuit
SPECIFICATION PARAMETERS Double chemical
CO 0-1000PPM 2000PPM 3-6na/6-9na/9-12na
1PPM -10℃-50℃ Normal±10% 15%-95%RH ≦60S
CATEGORY Time to recover Zero drift Stability Load
SPECIFICATION PARAMETERS ≦60S(Clean air) ≦5%(-10℃-40℃)
<5%/Year 250Ω
(Different circuit)
Linearty Linear Repetitive Drift Bias voltage Clearance Temp Life expectancy
<2% <5%/Year No request -20℃-60℃ 5year
无锡雷宏美电子科技有限公司 Wuxi LHMST electronic technology co., LTD Four、Element shape structure
                   注:PCO (L=20mm) Five、Electrical diagram
1、Response to restore graph(different output current and output)
2、Concentration of linear features(0-1000ppm CO)
3、Temperature characteristic figure
无锡雷宏美电子科技有限公司 Wuxi LHMST electronic technology co., LTD 4、Zero point temperature characteristic figure
Six、Anti-jamming performance
PCO will now sensor series of sensors on the response characteristics of the interference of several common gas column in the table below, for your reference. Data in the table is interference gas under a given concentration in the typical response parameters.
INTERFERE GAS
Interfere concentration
TEST TIME
PCO OUTPUT
CO 100ppm 5min 100ppm CH3CH2OH 2000ppm (CH3)3SiOSi(CH3)3
10min <10ppm
10ppm 40min 0ppm H2 200ppm 5min 50ppm C2H4 100ppm 5min 80ppm NO 35ppm 5min 6ppm H2S 100ppm 5min 0ppm SO2 20ppm 600min <2ppm
NO2 5ppm 600min <-1ppm
Note:
 Sensors to avoid contact with solvents (including silica gel and other adhesive) high concentrations,
coating, pharmaceutical, oil and gas;
 Gas ventilation face don't congestion, pollution, pore clogging is sometimes the cause of low sensitivity;  Sensor internal use of disposable packaging, please don't open the sensor;  Save the sensor electrode should be in short circuit condition;
 Before using the sensor must be aged not less than 24 hours, 48 hours is better!
 If is used for sensor problems on any questions, please consult the manufacturer's technical service
department in order to correctly use sensors.  Provide professional technical support!
Note: this manual is for reference only, the relevant changes no longer notice!!!!!!!!!!!