v1.0 可编辑可修改
FLOW-X 使用手册
1
1
目录
目录
I概述 ........................................................................................................................................................ 4 1 FLOW-X 流量计算机的概述 .............................................................................................................. 4 2 FLOW-X 流量计算机有如下特点 ...................................................................................................... 4 II FLOW-X流量计算机的接线 ................................................................................................................. 6 III 温度变送器...................................................................................................................................... 10 IV 压力变送器........................................................................................................................................ 11 V 485通讯............................................................................................................................................... 12 VI 脉冲通讯............................................................................................................................................ 16 VII 孔板流量计(orifice)通讯 ........................................................................................................ 17 VIII其他常用配置 ................................................................................................................................. 18 IX 常见问题............................................................................................................................................ 22
2
2
3
v1.0 可编辑可修改 3
v1.0 可编辑可修改 I概述
1 FLOW-X 流量计算机的概述
Flow-X在设计的时候专门考虑到其广泛的适用性。它可以工作在温度范围在0-60摄氏度(华氏32-140),湿度最高可达90%,不会冷凝。在实际运用中,Flow-x流量计算机通常安装在机架上放置在一个温度可控的房间内,比如控制室,机柜室或者辅助用室,或者分析站内。Flow-X对于国际的标定标准有着广范的支持,包括天然气、碳氢化合物液体,还有其他的一些功用:例如:AGA3, AGA5, AGA7, AGA8, AGA10;API Chapters , , and , API 2540, API1952 表格等;ISO 5167(所有版本),ISO6976(所有版本);NX19, SGERG, PTZ。
Flow-X产品可以为您的流量计量解决方案提供一个灵活的、可升级的平台。与Flow-X相比,其他的系统的灵活性通常意味着额外的设施配置,即使是为了实现一个很简单的功能。我们的Flow Express 基础版配置软件保证了简单的配置操作。而Flow Express高级版配置软件则可以在提供给用户超乎想象的自由空间的基础上,实现细节的配置。
2 FLOW-X 流量计算机有如下特点
安全性 计量密封性
所有的外壳都可以选配将流量计算机用铅封并设置一个安全系统,来防止由于转换到其他单独模块所带来的干扰。 在一个Flow-X/P(面板外壳)和一个Flow-X/R,有一个按钮可以控制一个铅封来封装所有的已安装的模块 干扰转换
每一个流量模块都配有一个机械的干扰转换装置用来阻止应用程序的改变或者程序内关键参数的改变 密码
如果要从前置面板或者电脑连接中进入参数或者功能的设置,可以设置一个密码来控制这个权限。 冗余
4
4
v1.0 可编辑可修改 如果,为了提高效用,需要一个冗余的解决方案。可以使用两个模块分别测量每个气流。 为了得到最大的效用,两个同样的Flow-X外壳可以使用这样变可以形成一个冗余的模式。
所有的模块都已经集成了双24V电源供给功能 快速数据交换。
5
5
v1.0 可编辑可修改 II FLOW-X流量计算机的接线
FLOW-X流量计算机背部接线端子为24V直流电源,1-4为24V正极,5-8为电源负极。FLOWSIC600超声波流量计、温度、压力变送器与FLOW-X流量计算机的接线如下:
6
6
v1.0 可编辑可修改 注: DB37针AO的接线为12+,13-
当使用温度使用四线制铂电阻变送器时,连接DB37的15 PRT 1 pwr+
16 PRT 1 sig+ 17 PRT 1 sig- 18 PRT 1 pwr-
图为DB37各个管脚功能
7
7
v1.0 可编辑可修改 图为DB9 Com口功能
图为24V电源功能
8
8
v1.0 可编辑可修改
图为网口接线图
9
9
v1.0 可编辑可修改 III 温度变送器
1 设置量程
IO → Configuration → Analog inputs
设置模拟通道的名称 设置温度变送器最高量程 设置温度变送器最低量程
2 设置模拟通道
Configuration → Run → Temprature
TT类型(模拟、PT100或HART) 设置通讯模块 设置模拟通道口 设置HART ID(连接电脑查看) 10
10
v1.0 可编辑可修改 IV 压力变送器
1 设置量程
IO → Configuration → Analog inputs
设置模拟通道名称 设置压力变送器最高量程 设置压力变送器最低量程
2 设置模拟通道
Configuration → Run → Pressure
PT类型(模拟或HART) 压力变送器类型(绝压或表压) 设置通讯模块 设置模拟通道口 设置HART ID(连接电脑查看)
以上温度压力设置需要严格按照图纸的接线方式,否则可能会导致温度压力信号混淆互换,以至计量出现问题。
11
11
v1.0 可编辑可修改 V 485通讯
(1) 选择Configuration → Run → Run Setup → Meter Device Type
状态应为“smart/pulse”
(2) 选择Configuration → Run → Flow meter → Pulse input → Pulse input
quantity type 状态应为“Volume”
(3) 选择Configuration → Run → Flow meter → Pulse input → Type of pulse
input
状态应为“Dual pulse input” (4) 选择System → Com Ports → Com 2
状态应为
(5) 选择Configuration → Run → Flow Meter → Smart Meter → Hart/modbus
Device ID 状态应为“1”
(6) 择Communications → Flowsic600 → Flowsic600 Communication
12
12
v1.0 可编辑可修改
(7) 选择Communication → Flowsic 600 overall status
(8) 选择 “path status” 应为
13
13
v1.0 可编辑可修改
(9) 选择 “path data”应为
14
14
v1.0 可编辑可修改
(10) 选择 “overall data”
15
15
VI 脉冲通讯
(1) 选择Configuration → Run → Run setup
状态应为“smart/pulse”
(2) 选择Configuration → Run → Flow meter → Pulse input → Pulse input
quantion type 状态应为“Volume”
(3) 选择 Configuration → Run → Flow meter → Pulse input → Type of pulse
input
状态应为“Dual pulse input”
(4) 选择Configuration → Run → Flow meter → Smart meter → Smart meter
input type
状态应为“HART/Modbus or Analog input”
注:流量计为485或者脉冲输入(“33,34”or“51,52”)时,状态为 “hart/modbus” 当流量计为4~20mA输入(“31,32”)时,状态为“analog input”
(5) 选择Configuration → Run → Flow meter → Smart meter → Pulse is
primary 状态应为“no”
(6) 选择 Flow meter → Meter k-factor → Nominal k-factor
查看流量计表头设定脉冲系数(如204lmp)
(7) 看脉冲接线“51和52”与DB37电缆所接的线头。查看表看数字输出端
选择IO → Configuration → Digital IO assignments → Digital “N” signal type
状态应为“pulse input N”
16
16
v1.0 可编辑可修改 VII 孔板流量计(orifice)通讯
(1) 选择Configuration → Run → Run setup → Meter device type
状态应为Orifice
(2) 选择Configuration → Run → Flow meter → Orifice 状态应为ISO5167或者AGA3 输入小流量切除值 输入管径 管道的参考温度(一般为20℃) 管道的膨胀系数 用户自定义管 DP直径 DP参考温度(一般20℃) DP膨胀系数 用户自定义DP膨胀系数 孔板的配置 压变的上下游位置选择 温变的上下游位置选择 温度校正(一般为绝热指数(Ie)) 道膨胀系数值
0 (3) 选择configuration→run→flow meter→DP inputs→DP selection
根据DP的数量选择DP selection type的类型,根据类型的不同,进入DP inputX,修改input type,analog input module,analog input channel
(4) 设置量程
IO→Module 1→Configuration→Analog Inputs(4—20mA)
17
17
v1.0 可编辑可修改 VIII其他常用配置
(1) 时间的设定
System → Device Setup(按格式要求严格输入)
(2) 清零
System → Reset
清除所有累积量 清除所有报表 清除所有事件记录 (3) 气体组份的设定
Gas propertied → Keypad composition
18
18
CH4 (甲烷) N2 (氮气) CO2 (二氧化碳) C2H6 (乙烷) C3H6 (丙烷) H2O (水) H2S (硫化氢) H2 (氢气) CO (一氧化碳) O2 (氧气) I-C4H10(异丁烷) N-C4H10 (正丁烷) I-C5H12(异戊烷) N-C5H12(正戊烷) Neo-C5H12 C6H14(己烷)
C7H16(庚烷) C8H18(辛烷)
(4) 累积量归档起始时间
Configuration → Overall Setup → Overall Setup → periods归档起始时间
(5) 参考温度、压力的标准
Configuration → Overall Setup → Overall Setup
19
v1.0 可编辑可修改 19
参考温度 参考压力
(6) 模拟输出的设定(AO)
Configuration→Run→Analog Outputs→Analog Output 1
AO输出类型 AO输出模块 AO输出通道
IO→Module 1→Diagnostics→Analog Outputs(查看数值变化) (7) 查看累积量历史记录
Period Data→Current Day/Hour,previous Day/Hour→Totals
当天累积量 前一天累积量 当前小时累积量 前一小时累积量 正向工况累积量 正向标况累积量 (8) 热值
Gas properties→Heating Value (9) 压缩系数
20
v1.0 可编辑可修改 20
In-use Values→Run→Compressibility (10) 声速算法
Flow meter→Smart meter (11) AGA8 算法
Configuration→Run→Gas Properties→Calculation Setup
Gross volume flow rate 工况瞬时流量 Base volume flow rate 标况瞬时流量 Mass flow rate 质量瞬时流量 Energy flow rate 能量瞬时流量 Meter temperature 流量计管道实时温度 Meter pressure 流量计管道实时压力
Cumulative gross volume total (forward) 工况总累积量 Cumulative base volume total (forward) 标况总累积量 Cumulative mass total (forward) 质量总累积量 Cumulative energy total (forward) 能量总累积量
21
21
IX 常见问题
看IP是否连接
选择system → modules → module 1 → Network
看network 1 station 是否为connect , 如果显示 not connect ,则通过模块修改IP,module中的IP地址要比panel中的地址大一位。 (2) 检查bus status
(3) 选择system → modules → module 1 → bus → bus status x
Bus status x 应显示状态为ok ,并观察bus RX 和 bus TX 状态,如果数值相近,则连接失败→修改模块module 1中 network的地址
22
22