Data File D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.DSample Name: CPK2015-914-05063=====================================================================Acq. Operator : Yang Qian(LCMS-02) Seq. Line : 50Acq. Instrument : HY-LCMS-02 Location : P2-F-01Injection Date : 9/15/2015 3:45:10 PM Inj : 1 Inj Volume : 3.000 µlAcq. Method : D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\100-1000MS+3MIN- 1.5_(0.02%FA).MLast changed : 9/15/2015 11:13:01 AM by Yang Qian(LCMS-02)Analysis Method : D:\\AGLIENT 1260\\DATA\\20150911\\20150911 2015-09-11 09-13-22\\100-1500MS+3MIN_ 1.5(0.02%FA).M (Sequence Method)Last changed : 9/15/2015 4:46:18 PM by Yang Qian(LCMS-02) (modified after loading)Method Info : Postive,MS:100-1000,Column ID:A-RP-102,40℃ Catalog No : HY-10214 Batch#05063 A-RP-134 Additional Info : Peak(s) manually integrated DAD1 B, Sig=214,4 Ref=off (D:\\AGLIENT...0\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.D) 2.084 1.562 1.777 2.186mAU14001200100080060040020000.51 2.3521.522.53min ===================================================================== Area Percent Report ===================================================================== Sorted By : SignalMultiplier : 1.0000Dilution : 1.0000Do not use Multiplier & Dilution Factor with ISTDs Signal 1: DAD1 B, Sig=214,4 Ref=off Peak RetTime Type Width Area Height Area # [min] [min] [mAU*s] [mAU] %----|-------|----|-------|----------|----------|--------| 1 1.562 MM 0.0453 4.11423 1.51270 0.0953 2 1.777 MM 0.0448 9.26160 3.44908 0.2145 3 2.084 MF 0.0462 4293.160 1550.22510 99.4525 4 2.186 FM 0.0200 5.65672 4.70747 0.1310 5 2.352 MM 0.0548 4.60763 1.40075 0.1067 Totals : 4317.53179 1561.29511 ===================================================================== *** End of Report ***HY-LCMS-02 9/15/2015 4:46:19 PM Yang Qian(LCMS-02)Page 1 of 1
Data File D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.DSample Name: CPK2015-914-05063=====================================================================Acq. Operator : Yang Qian(LCMS-02) Seq. Line : 50Acq. Instrument : HY-LCMS-02 Location : P2-F-01Injection Date : 9/15/2015 3:45:10 PM Inj : 1 Inj Volume : 3.000 µlAcq. Method : D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\100-1000MS+3MIN- 1.5_(0.02%FA).MLast changed : 9/15/2015 11:13:01 AM by Yang Qian(LCMS-02)Analysis Method : D:\\AGLIENT 1260\\DATA\\20150911\\20150911 2015-09-11 09-13-22\\100-1500MS+3MIN_ 1.5(0.02%FA).M (Sequence Method)Last changed : 9/15/2015 4:47:13 PM by Yang Qian(LCMS-02) (modified after loading)Method Info : Postive,MS:100-1000,Column ID:A-RP-102,40℃ Catalog No : HY-10214 Batch#05063 A-RP-134 Additional Info : Peak(s) manually integrated MSD1 TIC, MS File (D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.D) ES-API, Pos, Sc 2.08850000040000030000020000010000000.511.522.53min HY-LCMS-02 9/15/2015 4:47:14 PM Yang Qian(LCMS-02)Page 1 of 2
Data File D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.DSample Name: CPK2015-914-05063MS Signal: MSD1 TIC, MS File, ES-API, Pos, Scan, Frag: 50 Spectra averaged over upper half of peaks. Noise Cutoff: 1000 counts. Reportable Ion Abundance: > 10%. Retention Mol. WeightTime (MS) MS Area or Ion 2.088 2732604 466.20 I 465.20 I*MSD1 SPC, time=2.072:2.108 of D:\\AGLIENT 1260\\DATA\\20150915\\20150915 2015-09-15 11-13-01\\CPK2015-914-05063.D ES-API100806040200100200300400500600700800900m/z 466.2 465.2Max: 357440 *** End of Report ***HY-LCMS-02 9/15/2015 4:47:14 PM Yang Qian(LCMS-02)Page 2 of 2